English (United States) Italiano (Italia)  |     |  Login
 
ALUMINIUM OPEN CELL CEILING SYSTEMS


 

PARTICULARLY SUGGESTED TO SHIELD ABOVE THE CEILINGS:
• Smoke and gas signal devices
• Loudspeakers for music or informations
• Extinguish sprinklers fire safety
• Get in signal bell alarm
• Safety and control videocameras

FIRE:

Open cell ceiling allows heat and smoke to rise in a fire, therefore existing venting may e retained and as well the extra void accepting the smoke allows valuable minutes for people to evacuate the building.

MATERIAL: Our open cell ceiling are manufactured from non-combustible material, which does not give off toxic smoke.
VENTILATION: Open cell ceiling is increasing the area by using the space above and under the ceiling heat Build-up from lights, workingfloor etc. rapidly dissipates to above ceiling space through the open cells preventing undue heat.
SECURITY: Security checks can be carried out easy through the ceiling as required, which is a must now and for the future.
VISUAL: Open cell ceiling offers an interesting and distinctive three dimensional ceiling with shape, colour and lighting.
NOISE: Where lot a people are coming together normally it's very noisy and unpleasent. Open cell ceiling is absorbing this to a normal level.

Download Catalogue: OPEN CELL CEILINGS aluminium corrosionproof

For further details click the link: OPEN CELL CEILINGS

COKI-U TRADIZIONALE











TECHNICAL SPECIFICATION
:

Open cell ceilings concealed system Type METALSCREEN COKI-U TRADIZIONALE prepainted aluminium corrosionproof incombustible class 0 - Euroclass fire reaction A1 (colour and mesh cells dimension choosed by the consultant).
The Type METALSCREEN COKI-U TRADIZIONALE open cell ceilings system is composed by U shaped profiles base width mm.10 and height mm.40.
Combine all the required components made of aluminium of the same colour it will obtained a regular open cell ceilings without any joints or visual interruption.
To obtain better soundproofing, the U shaped blades con be microperforated Ø mm.2 with acoustic TNT non woven thermal applied on the back.


UPON REQUEST THE BLADES CAN BE ASSEMBLED IN PANELS mm.600x600


INSTALLATION GUIDELINE COKI-U TRADIZIONALE
Click the link

 

To visualize PhotoGallery Type Coki-U Tradizionale clic on the picture 

 

 

COKI-U APPOGGIO


























UPON REQUEST THE BLADES CAN BE ASSEMBLED
IN PANELS mm.600x600

TECHNICAL SPECIFICATION:

Open cell ceiling lay-in system Type METALSCREEN COKI-U APPOGGIO T24 prepainted aluminium corrosionproofincombustible class 0 - Euroclass fire reaction A1 (colour and mesh cells dimension choosed by the consultant). The open cell ceiling panels must have Ushaped section base width mm.10 or mm.15 and height mm.40 (the base width dimension choosed by the consultant). The Type METALSCREEN COKI-U APPOGGIO open cell panels mm.600x600 will be installed lay-in on exposed T bar grid mm.600x600xH38 system TWIN LOCK mm.24xH38 of the same colour as the open cell ceiling. Each panel must be easily removable for inspection. The modular panels mm.600x600 are easily individually laid and taken out of the standard T grid, by lifting them upwards for simple access to the plenum.


Total full inspection - Each panel removable - Fast installation -  Quick maintenance

 

To visualize PhotoGallery Type Coki-U Appoggio clic on the picture 

 

 

COKI-B15









TOTAL FULL INSPECTION-
REMOVABLES
TECHNICAL SPECIFICATION:

Open cell ceilings lay-in systemType METALSCREEN COKI-B15 prepainted aluminium corrosionproof incombustible class 0 - Euroclass fire reaction A1. (colour and mesh cells dimension choosed by the consultant). The Type METALSCREEN COKI-B15 open cell must have U shaped section width mm.15xH38,5 to became a panel mm.600x600 complete of the lateral edge cover profile in aluminium same colour as the open cell panel. It will be installed lay-in on exposed T bar system TWIN LOCK mm.600x600xH38 with the base mm.15 of the same colour of the cell ceilings to abtain the perfect aesthetical result without any joint or visual interruption. Each panel must be easily removable for inspections. The peculiarity and particularly is to obtain a lay-in open cell ceiling without differences between the panels and the T bar system that must be of the same module width mm.15. To obtain better soundproofing, the U shaped blades con be microperforated Ø mm.2 with acoustic TNT non woven sticked on the back.


UPON REQUEST THE BLADES CAN BE ASSEMBLED IN PANELS mm.600x600

 

BENEFITS

  • Easy to install and remove for service integration
  • Decorative solutions achieved through a variety of cell sizes

APPLICATION AREA

  • Recommended for shops, supermarkets, shopping centres, entrance areas, airports, railway stations and showrooms.

HUMIDITY EXPOSURE

Up to 95% (for short term exposure)

SERVICES INTEGRATION

The open cell nature allows coordination and integration of service elements within the cells of the tiles. The actual size of the cell openings is the cell module size minus 15 mm.

CLEANING

Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended.

QUALITY STANDARD

Certified EN ISO 9001:2008 Quality Assumed Manufacturer. Ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material.

ENVIRONMENTAL

Our European manufacturing plants are certified to:
ISO 14001:2004 + Cor.1:2009 
member of TAIM (Technical Association of Industrial Metal Ceilings).

 

 

 

 

 To visualize PhotoGallery Type Coki B15 clic on the picture 

 

 

Products

 

Download

Download il 
2018 Brochure controsoffitti

 

Download 
2018 Catalogo esterni 
Rivestimenti controsoffitti frangisole schermanti per esterno

 

Download 
2018 New Technical Catalogue 
for External Claddings 
and Petrol Gas Stations 

 

 

Download
New Technical Catalogue
METALSCREEN 2018

 

Download
New Technical Catalogue 
for Hospitals

METALSCREEN 2017

 

Download
Catalogo 
New Technical Catalogue
Screen Ceilings 
Panels

 

Download
Tavane False
Romania

  

 

Contacts

 

FALSE CEILINGS INDUSTRIES
BUILDING PROFILES AND SUSPENSION SYSTEMS FACTORY

VIA ALDO MORO, 38
41030 BOMPORTO MODENA - ITALY EU

Ph.  +39 059 8170611
Fax +39 059 8170633
E-mail: metalscreen@metalscreen.it


Quality Management System Operated
UNI EN ISO 9001

European Test Approval
EN 13964:2007
EN 14195:2005

METALSCREEN g.e.e.e.
False ceilings industries building profiles and suspension systems factory
41030 BOMPORTO MODENA ITALY EU - Via Aldo Moro, 38

Tel. +39 059 8170611 - Fax +39 059 8170633
Web: www.metalscreen.it -  E-mail: metalscreen@metalscreen.it - Metalscreen

 

Copyright 2018 by Metalscreen g.e.e.e. Srl   |  Privacy Statement  |  Terms Of Use